D10 NO RESET.

D110 NO RESET.

D2 While holding down WRITE, press SYSTEM. Then press ENTER twice.

D5, D20, D50, D550, D70 NO RESET.

DR202 Power on while holding down MUTE and ROLL. Use the VALUE DIAL to select ALL and press TAP/ENTER twice.

DR5 Power on while holding down the FRET LEFT (<) and RIGHT (>) buttons, then press ENTER twice.

DR550, mkii Power on while holding down the -1 and +1 buttons, then press the START button.

DR660 Press UTILITY, then use LEFT (<) and RIGHT (>) to select [8] INIT. Press the ENTER button twice.

DR670 Power on while holding down the REC and STOP/CONT buttons, then press ENTER twice.

DR770 Press UTILITY then CURSOR (>) to 9.F.RST. Use the VALUE DIAL to select ALL and press ENTER twice.

JD800 Press DATA TRANSFER. Use page UP and DOWN to select FACTORY PRESET, then press ENTER.

JD990 While holding EXIT, press UTILITY. Press F6 (EXECUTE) and the F5 (YES).

JP6, JP8 NO RESET

JP8000 While holding down the SHIFT button, press INIT/UTIL. Press INIT/UTIL again until you get INITALIZE WRITE in the screen. Use the DOWN and UP buttons to select FACTORY PRESET, then press the WRITE button.

JP8080 Press EDIT and then Bank 7 (also labeled INIT/UTIL) several times to access

""FACTORY RESET

"" in the display. Press DEC or INC to select ALL in the screen and then press REC followed by WRITE.

JS30 Power on while holding down the RECORD button, located in the sequencer section.

JS5 Press UTILITY then CURSOR (>) to

""Factory Reset?

"". Press ENTER twice.

JUNO 1,2,6,60,106 NO RESET

JUPITER 6, 8 NO RESET

JV1000 Power on while holding down the NUMBER 8 button (also labeled PERFORM and CAPS), press ENTER then press WRITE.

JV1010 While in PERFORM mode, press the VOLUME KNOB and VALUE KNOB together. Turn the CATEGORY/BANK KNOB to PIANO and press the VALUE KNOB twice.

JV1080 Press UTILITY, cursor down once, then cursor right three times to select FACTORY PRESET. Press ENTER twice, then press UTILITY.

JV2080 Press UTILITY. Press F6 twice to select MENU 3. Press F1 and then F6 (turn the

""memory protect

"" to OFF if necessary using the VALUE DIAL). Press F6 twice.

JV30 Press CHORUS and REVERB (above INITIALIZE) simultaneously. Press VALUE UP.

JV35 Press CONTROL and MASTER simultaneously. Press PARAMETER UP or DOWN to select ALL. Press VALUE UP.

JV50 Press CONTROL and MASTER simultaneously. Press PARAMETER UP or DOWN to select ALL. Press VALUE UP.

JV80 Power on while holding down the NUMBER 8 button (also labeled PERFORM and CAPS), press ENTER then press WRITE.

JV880 Press UTILITY, then use the DATA DIAL to select FACTORY PRESET. Press ENTER twice.

JV90 Power on while holding down the NUMBER 8 button (also labeled PERFORM and CAPS), press ENTER then press WRITE.

JW50 Press TUNE/FUNCTION. Press F5 (FACTORY), then F4 (JW RESET), then F3 (GS RESET), then F4 (YES).

JX1 Power on while holding down WRITE and FLUTE.

JX10 NO RESET.

JX3P NO RESET.

JX8P NO RESET.

R5 Power on while holding down CURSOR PAGE and PARAM SELECT, then press the ENTER button twice.

R70 Power on while holding down the MIDI and ASSIGN buttons.

R8 Power on while holding down CURSOR PAGE and PARAM SELECT, then press the ENTER button twice.

R880 NO RESET.

R8M Power on while holding down ENTER and RIGHT (>) CURSOR, then press the ENTER button twice.

R8MKII Power on while holding down CURSOR PAGE and PARAM SELECT, then press the ENTER button twice.

W30 NO RESET

W50 Press CONTROL and MASTER simultaneously. Use PARAMETER UP and DOWN to select ALL

W50 Press CONTROL and MASTER together. Use the PARAMETER UP and DOWN buttons to select ALL. Then press the VALUE UP button.

XP10 Press UTILITY. Use the VALUE + or - to select INITIALIZE, then press ENTER. Use the VALUE + or - to select FACTORY PRESET, then press ENTER.

XP30 Press UTILITY/CARD. Press the CURSOR DOWN then press #4 (BASS). Press ENTER (if protect message appears, use the DIAL to turn the Memory Protect OFF, then press ENTER twice).

XP50 Press DISK/UTILITY. Select SOUND, then select PRESET and press ENTER. Use the DIAL to turn the Memory Protect OFF if necessary, then press ENTER twice.

XP60 Press UTILITY then F6 twice to select FACTORY and press ENTER. Press F6 (EXECUTE), then use the DIAL to turn the Memory Protect OFF if necessary, then press ENTER then press F6 (EXECUTE).

XP80 Press UTILITY then F6 twice to select FACTORY and press ENTER. Press F6 (EXECUTE), then use the DIAL to turn the Memory Protect OFF if necessary, then press ENTER then press F6 (EXECUTE).

XV2020 While in PERFORM mode, press the VOLUME KNOB and VALUE KNOB together. Turn the CATEGORY/BANK KNOB to PIANO and press the VALUE KNOB twice.

XV3080 Press UTILITY and the CURSOR DOWN to UTIL page 2. CUROSR (<) or (>) to make the FACTORY RESET flash. Press ENTER three times.

XV5050 Press UTILITY and then CURSOR LEFT. Turn the VALUE DIAL to select FACTORY RESET and press ENTER twice.

XV5080 Press SYSTEM/UTILITY so that the light starts blinking. Press F6 (MENU) and then F5 (FACTORY). Then press F6 (EXECUTE).

XV88 Press UTILITY and then CURSOR DOWN to UTILITY page 2. Press 4(BASS) and then ENTER twice.